2019 Valid NACE CIP Level 1 NACE-CIP1-001 Dumps
April 22,2019
The current IT industry demands a reliable NACE-CIP1-001 exam dumps,so that you pass your NACE-CIP1-001 NACE Coating Inspector Level 1 exam in minimum possible time and without wasting much of your money and energies.Passcert offers you valid CIP Level 1 NACE-CIP1-001 dumps to practice and 100% help you pass successfully.
To become a coating inspector, you need to pass two levels of certification – CIP Level 1 and CIP Level 2. Passcert offers Coating Inspector bundle of CIP Level 1 NACE-CIP1-001 and CIP Level 2 NACE-CIP2-001 dumps to help you pass your exams easily.
CIP Level 1 NACE-CIP1-001 Information - NACE- Coating Inspector Level 1 written Exam
The Coating Inspector Level 1 written exam is designed to assess whether a candidate has the requisite knowledge and skills that a minimally qualified Level 1 Coating Inspector must possess. The 100 multiple-choice questions are based on the Coating Inspector body of knowledge. A candidate should have entry level knowledge of all corrosion, surface preparation, cleanliness, environmental conditions, test instruments, coating mixtures, safety, and can perform basic and non-destructive inspections of liquid coatings applied by brush, roller or spray to steel surfaces under the supervision of a level 2 or 3 inspector when working in a shop setting or a level 3 inspector when working in a field setting.
Target Audience
A Level 1 Coating Inspector is responsible for performing and documenting basic and non-destructive inspections of liquid coatings applied by brush, roller or spray to steel surfaces under the supervision of a level 2 or 3 inspector when working in a shop setting or a level 3 inspector when working in a field setting.
Upon successful completion of requirements, the candidate will be awarded a NACE Coating Inspector Level 1 -Certified.
NACE Coating Inspector Level 1 NACE-CIP1-001 Test Objectives
Domain 1- Saftey - 2.5%
Domain 2- Inspection Process - 15%
Domain 3- Corrosion - 5%
Domain 4- Environmental Controls and Inspection - 5%
Domain 5- Surface Preparation and Inspection - 20%
Domain 6- Coatings and Inspection - 20%
Domain 7- Coating Application - 7.5%
Domain 8 - Documentation - 10%
Domain 9 - Standards - 10%
Domain 10 - Team Work - 2.5%
Domain 11- Ethics - 2.5%
CIP Level 1 NACE-CIP1-001 Sample Questions
NACE-CIP1-001 sample questions are included to illustrate the formats and types of questions that will be on the exam.
1.You are the NACE Inspector on a tank lining project where a 50% solids epoxy tank lining is being applied. After application of the 19 coat you notice small blisters in some areas of the applied lining.
Your FIRST preferred course of action is to:
A. Break the blisters to see what's inside
B. Document the problem and advise the Contractor and Owner's representative
C. Document the problem and advise the Contractor
D. Extract any liquid that may be inside the blister and send it to the lab for further analysis
Answer: B
2.Dew point is the temperature at which
A. water freezes.
B. humidity decreases
C. condensation occurs.
D. the air is saturated.
Answer: C
3.If a contractor is using a poorly maintained compressor to supply air for abrasive blast cleaning and conventional airspray, the coating inspector should perform a
A. dry film thickness (DEI) measurement.
B. wet film thickness (WFT) measurement.
C. blotter test for the presence of oil and water.
D. vial lest.
Answer: C
4.Upon arrival of coating materials, the inspector should
A. review coating contractors' plans for storage of coating materials and confirm they meet national, local and owners' fire and environmental regulations.
B. observe and document the amount of material and batch numbers.
C. observe aryl document that the applicator WFT at regular intervals during application.
D. observe and document time frame and environmental conditions between each coat.
Answer: B
5.Relative humidity is
A. a measure of the amount of moisture in the air compared to saturation level.
B. a measure of the amount of moisture in the air compared to the air temperature.
C. the lowest temperature at which moisture forms on a steel surface.
D. the highest temperature at which moisture forms on a steel surface.
Answer: A
6.Galvanic corrosion occurs on which of the following substrates:
A. Concrete
B. Fiberglass Reinforced Plastic
C. Metal
D. Wood
Answer: C
7.When applying Thermal Spray Coatings the specification is most likely to refence:
A. SSPC PA 2
B. NACE SP 0178
C. NACE SP 0188
D. SSPC-CS 23.00/AWS C2.23/NACE No. 12
Answer: D
8.What is the minimum recommended distance away from an edge that an inspector should take a measurement with a dial-type magnetic pull-off Dry Film Thickness (DFT) gauge?
A. 1 cm (.39 inch)
B. 2.5 cm (1 inch)
C. 6.35 cm (2.5 inch)
D. 2.5 millimeters (.10 inch)
Answer: B
- Related Suggestion
- NACE CIP Level 2 CBT Exam NACE-CIP2-001 Dumps April 26,2019
- How to Become a Coating Inspector - CIP Level 1 and CIP Level 2 February 19,2019
- 2022 Latest Coating Inspector Program Level 1 NACE-CIP1-001 Dumps March 24,2022
- 2022 Valid Coating Inspector Program Level 2 NACE-CIP2-001 Dumps March 23,2022